Installation Instructions
 Head Shower Installation· Decorative cover · Screws · Pipe 1 · Pipe 2 · Screw · Bolt · Nut · Water Inlet Pipe |  hole size on ceiling1. Drawing the line on the ceiling according to the above specification · Decorative Cover · pipe 1 2. connect pipe 1 with decorative cover |

3. Drill the holes on the ceiling according to the above hole specification and install 4 pipes. 4. According to the right drawing, install four-pipe 2 into pipe 1. Put the screw bolts through the hole on the side to lock pipe 2 with pipe 1. |  5. As the right drawing is shown, install four-pipe 2 on the head shower.6. After fixing the showerhead on the ceiling, connect the shower hose with 2 water inlet on the showerhead back cover. The other end connects with the water outlet pipe in the wall. |

|  |

Remarks: Ceiling mounted shower head
come with fixing bar installation 1. Draw size on ceiling
2. Install fixing bar on ceiling

3. Install fixing bar on shower head

4. Put shower head bar on ceiling
fixing bar. The showerhead installation is now
complete.
Hand Held Shower Installation


Parts List
A. Hand Shower
B. Wall Anchors (x2)
C. Screws (x2)
D. Wall Bracket
E. Cap
F. Hose
G. Screen Washer
Place the screen washer in the end of the handshower hose. Screw the hose to the handshower.If the flow of water becomes noticeably less, remove and clean the screen washer.
Scale Removal

The handshower incorporates the cleaning system. If scale deposits are noticed in the spray channels, turn the water on lightly and rub the spray channels with a finger or a sponge.
If scale deposits are noticed on the spray face, pour about 3/4" of a commercial scale remover into a shallow dish. Dilute the remover according to the label instructions.
Soak only the spray face in the solution for the amount of time specified on the label.
Rinse the handshower with clear water.
Reinstall the handshower. Turn on the water and al-low the handshower to flush for at least one minute.


Parts Lis
A. Connector B. Connector Screws (x2) C. Bracket Screws (x4) D. Bracket E. Plaster Guard F. Test Plug G. Test Plug Nut H. 1/8" Hex Wrench I. Housing | J. Housing Nut K. Spray Assembly L. Grease Packet M. Trim Ring-Square N. Trim Ring-Round O. Set Screw P. 9/64" Hex Wrench Q. 1/16" Hex Wrench R. Filter |

1" Extension Service Kit
* Not Included
Rough-In Installation

5. Plumb the connector to water supply lines.

Rough-In Complete
Trim Installation


12. If distance is less than or equal to 2-1/8" (54mm), proceed to step 13. If distance is greater than 2-118", order 1" extension kit.
13 (A). Tighten housing nut (J) until housing (I) is secure and does not spin on wall.
14. Flush system before next step.

Reduced Flow Turn off water supply
To Re-install:Reverse steps A through C, then turn on water supply.
Digital Controller Installation
Operation ·
Fly-shuttle switch
·
Setting
·
Power on/off
·
LCD Display
Notice
1. The control panel is sensitive,
when you install it, please avoid to let it face directly to the water from
hand shower and the head shower because water will get it misoperation or lock
the control panel.
2. The touch button is the best
sensitive area.
3. The touch panel has water splash
protection technology. When the system detects misoperation, no response, and need
about 1 second to recover.

Function
1. Water TEMP adjust
2. Hand shower
3. Head Shower
4. Water flow adjust
Operation
1. Power on/off
Power on
After electrify, you can touch to make the system ON. When you hear buzzer
sound, the fly-shuttle switch and the LCD panel would be lighting. Water TEMP
and water flow will be the same as that you set last time. The cursor will be on
the icon you using last time. The default working time is 60 minutes.
Power Off
When the system on, touch again to make the system OFF or the default working time is up, when you hear buzzer sound that means have close all the functions.
NOTE: (the background color of the fly-shuttle switch)LED show blue color when TEMP below
33° C
LED show orange color when water
TEMP between 34° C- 41° C
LED show red color when water TEMP
over 41° C
2. Hand shower and head shower switch
When system on, rotating the fly-shuttle button left or right. the cursor would move to icon, pressing the fly-shuttle button to open hand shower or head shower (hand shower and head shower are inter-locked, you can turn on only one time), the corresponding operation icon would brighten up on the LCD panel after turning on. The cursor could move to icon, pressing again the fly-shuttle button to close hand shower or head shower, the corresponding function icon would be dark.
Battery Installation
1. Loose the screws on the battery
cover and take it off.
2. Putting 4 pcs rechargeable
batteries into the battery slot of the host box.
Attention: When putting the battery into the host box, you need to identify the anode and the cathode.
1. Insert the battery cover into the host box, and Lock it with the screws.
Caution:
•
Using rechargeable NI-MH battery
[the 5#(AA) and the capacity is more than l000Mah).
•
After electrify, forbid using the
normal 5#(AA) battery. Otherwise, would cause the battery explosion.
•
When the power cut, you can use the
high quality normal 5#(AA) dry battery as the emergency measure. But you must
unplug the adapter.
•
When you install the host box,
please put the battery into it. If the product hasn't connected with the power
in a long time. Please take out the battery from the host box. This way can
avoid affecting the battery working life.
•
If you want the battery with a longer
working life, you can charge the battery every some months.
Installation of the Control Panel
There are two kinds of installation
ways shower controller according to the installation site, one way is to recess
mount into the wall. Another way is to build into the shower panel.
1.
Build the control panel into the
shower panel
Step
1: Open a hole (6.7" X 3.7")
on the shower panel, putting some glass cement around the back of the control
panel and fit it in the hole of the shower panel as picture shown.
Step
2: Fasten the mounting bracket onto
the back of the control panel by screws.
Step
3: Install the host box on the back of
the shower panel, connect the cold water and hot water pipe, hand shower, and
head shower's pipes.
1. Connect the G1/2" hot and
cold water inlet pipes to the host box, tighten it and make sure connection is
well sealed (as the picture showed).
2. Connect the G1/2" water
inlet pipe of the faucet to the water outlet pipe of the host box, tighten it
and make sure connection is well seated (as the picture is shown).
Caution:
• When installation, the hot water
pipe, and the cold water pipe cannot mix up. Otherwise, the system cannot work.
• When you tighten the connector nut, torque
should not exceed 8NM, GB 2.5NM is OK, otherwise, it will damage the connector
of the mixing valve and lead to water leaking.

Step
4: Connect the host box control cable
with the control cable of shower faucet as an arrow mark on the picture.
Caution:
When connecting the two control cables,
you must follow the arrow mark which is shown in the cable joint. If not, it will
damage the cable joint.
Step
5: Connect the power supply cable of
the host box with the adapter.

2. Recess mounted into wall
According to the wall thickness, you
can choose installation method A or B.
Method
A: If the wall is thin, the host box
and the shower control panel can be installed in a different position.
Method
B: If the wall is thick, the host box
and the shower control panel can be installed in the same position.
Installation
step of method A:
Step
1: Open two-hole in the wall, and
reserve space for the pipes and adapter.
Step
2: Dill four holes by 6mm diameter on
the upside hole for install the wall bracket (as the picture) and put the
plastic screw into the hole.
Step
3: Drill four holes by 8mm diameter on
the downside hole for the host box installation and put the expansion screws
into the hole.
Step
4: Install the wall bracket of control
panel and the host box in two holes, according to the pipe's position to set
the host box position, adjust the screw of wall bracket to make sure it is
concave the wall surface with a 0.5-1 mm difference.
Step
5: Connect the water pipe and the
power supply cable of the host box, get water supply to make sure the pipe has no
leak. Connect the host box control cable to the control panel hole and fasten
it, using the cement to seal the wall and cover by the tiles.
Step
6: Connect the control cable between
the host box and the control panel put some silicon on the back case of the
control panel and put it on the wall bracket.