Melun Dark Oil Rubbed Bronze Infrared Automatic Electronic Commercial Faucet
The Melun Dark Oil Rubbed Bronze Infrared Automatic Electronic Commercial Faucet
Commercial Automatic Faucet; Designed for precise activation, controlled water output, and long-cycle durability. Improve hand washing compliance, and minimize waste of water, by using BathSelect touchless bathroom automatic faucet. Immediately reduces water waste by eliminating unnecessary and unattended water flow. BathSelect touchless faucet comes with AC/DC option (hardwired and battery backup) Water Pressure: 0.5 - 7.0 KGS/cm, 10-125 psi. Touchless operation; specifically designed for optimal performance in various commercial use applications, making it ideal for public restrooms, restaurants, office buildings, public facilities and hospitals. Fits all standard US plumbing.
Sensor faucet complete motion detection operation.
Sensitive Sensor with Infrared AI Smart-Chip
Factory set to 30-second Auto Shutoff (can be adjusted).
Water Pressure: 0.5 - 7.0 KGS/cm, 10 - 125 psi
Solid Brass Construction, Dark Oil Rubbed Bronze
Installation made easy with simplified instructions
Water resistant solenoid enclosure
Advanced energy saving design for long lasting battery life
Comes complete with Hoses & Accessories
Power Supply: AC110V And DC6V (batteries not included)
AC/DC power option.
ADA Compliant.
Can be installed in new or retrofit applications.
Usage: Commercial
Touchless operation; specifically designed for optimal performance in various commercial use applications, making it ideal for public restrooms, restaurants, office buildings, public facilities and hospitals. Fits all standard US plumbing.
Reduces the transfer of germs by preventing cross-contamination and re-contamination of germs and bacteria by not touching the faucet handles. Cut down on water usage by minimizing and eliminating unnecessary, unattended water flow.
Sensor Activated Faucet Special Features:
Durable Vandal-Resistant Brass Body; Ideal for commercial high traffic use applications
Intelligent: with its micro-computer controlling its action, the faucet will self-adjust its best detection zone as per the color and shape of the lavatory
Flashing light indicator; a diagnostic indicator for power up, low battery, and solenoid function.
The meanings of the codes are described in the installation instructions.
Convenient to maintain; with a built-in strainer to prevent sundries from entering the solenoid valve and the strainer is easy to clean
The faucet can be mounted to any sink surface.
ADA Complaint
The battery's life is 8,000 cycles per month and with enough water pressure is approx 5 years service life of the batteries.
Adjustable sensing range; while the factory range is set about 4"to 5" from the sensor, it can be adjusted.
Diameter of inlet pipe: DN15
Diameter of outlet pipe: DN15
Water Pressure: 0.05Mpa - 0.7Mpa
Power and Voltage: DC.6V AC.220V - 50/60Hz
Power Consumption: 0.5MW <2W
Detection Zone: Factory sets 25cm/10" (based on standard inductive board)
Ambient Temperature: 1 - 45 ℃ / 33.8 -113 °F
Degree of protection by enclosure: 1P56
A great addition to public bathroom, hotels, restaurants, public places, government facilities...!
This Sensor Faucet Applications; Residential, Commercial use & ADA
This faucet is shipped complete. ANSI A112.18.1M CSA Standard B125, 2.2 U.S.
GPM Complies with NSF Standard 61, Section 9
Flow Preventers Stainless Steel Hoses Mounting Hardware Batteries Pre-installed
All the hardware necessary for satisfactory installation
Specifications and Dimensions
Spout: Chrome Plated Solid Brass Power: 4 (AA) Alkaline
Batteries or AC Adapter
Battery life expectancy: 250,000 cycles Solenoid valve: 6 Volt magnet latching
Working Water Pressure: 1 PSI -100 PSI
Supply Inlet Size: 1/2†NPT Male
Water Temperature Control;
check
Options for temperature control sensor faucets
Built-in Pop-Up Drain
Rod: N/A
Sensor type and Location: Active Infrared, Neck mount Sensor
Microprocessor: Digital, Pug And Play Sensing Range: 2†to 6â€
Response Time: 0.3 Second
Shut-Off Delay Time: 2 Seconds
Anti vandalism maximum Running Time: 60 Seconds
Particle filter size: 50
Mesh Aerator: 2.2 GPM Standard
Features
We're available to provide assistance and support for your inquiries!
Featured
categories
MELUN COMMERCIAL SENSOR LINE
Melun Sensor™
Technical FAQs
Commercial touchless faucet with solid brass construction,
adaptive infrared sensing, AC/DC power, adjustable detection,
serviceable filtration and anti-vandal automatic shutoff.
✥
How Does the Sensor Self-Adjustment Work?
+
The microcomputer-controlled infrared system automatically
adjusts its detection behavior according to the color and
shape of the installed lavatory. Final commissioning should
be completed after the basin, countertop and surrounding
surfaces are fully installed.
◇
What Is the Factory Detection Zone?
+
The factory detection zone is approximately 25 cm or
10 inches based on the standard inductive board. The
operating sensing field can also be adjusted during
commissioning to suit basin depth, user approach and
surrounding reflective conditions.
◯
What Water Pressure Is Supported?
+
The commercial specification lists approximately
0.05 to 0.7 MPa and 10 to 125 PSI operating pressure.
Flush the supply lines before final connection and
verify stable dynamic pressure before commissioning
the electronic valve.
↻
How Does the Automatic Shutoff Operate?
+
The faucet is factory configured with an approximately
30-second automatic shutoff that can be adjusted where
required. The system also incorporates a 60-second
anti-vandal maximum running time to limit prolonged
unattended water discharge.
⌁
How Fast Does the Sensor Respond?
+
The active infrared control provides approximately
0.3-second response after valid hand detection.
The specified shutoff delay is approximately 2 seconds
after the user exits the sensing field, helping balance
responsive operation and water efficiency.
⌂
How Is the Solenoid Protected From Debris?
+
A built-in serviceable strainer prevents sediment and
foreign material from entering the solenoid valve.
During scheduled maintenance, isolate the supply,
clean the strainer and confirm unrestricted flow before
restoring the faucet to service.
⚡
Which Power Configurations Are Supported?
+
The faucet supports AC110V and DC6V operation, allowing
hardwired or battery-powered installation depending on
the supplied configuration. Verify the specified power
components before connecting and commissioning the
sensor control system.
⌕
What Should Routine Maintenance Include?
+
Clean the sensor window and aerator, inspect the built-in
strainer, verify battery or AC power condition and confirm
reliable solenoid shutoff. The electronic enclosure is
specified with IP56 protection for commercial installation
conditions.
‹
›
Dark Oil Rubbed Bronze
Dark Oil Rubbed Bronze
Brushed Gold
Brushed Nickel
Light Oil Rubbed Bronze
♧
2.2 GPM
Standard Aerator
◇
Solid Brass
Commercial Construction
⌁
25 cm
Factory Detection
⚙
IP56
Protected Controls