Technical Resources for Touchless Faucet Systems

Real links for BIM/Revit, CSI specs, installation & commissioning, telemetry, and certifications — tuned for airports, offices, transit hubs, and stadiums.

Training Videos

Short demos for installation & operation (replace with your project videos anytime).

Sensor Faucet
Finish Options
Wall-Mounted

Installation Essentials

Hydraulics
0.35–0.5 gpm laminar; 60–80 psi regulation; hot recirculation where applicable.
Mixing & Safety
Anti-scald via ASSE 1070/ASME A112.1070/CSA B125.70; ≤120°F (49°C) outlet.
Filtration
Y-strainer 200 μm (feeds); inline soap filter 80–100 μm (multifeed).
Electrical
100–240 VAC primary; battery failover ≥ 400k activations; optional low-voltage/PoE raceways.
Durability
Electronics IP65+; IK10 plates; locking M8/M12 connectors.

Commissioning Checklist

Response
Verify activation delay ≤ 200 ms (ToF); tune dwell & shutoff.
Sanitation
Schedule purge/flush; validate thermal disinfection routines.
Integration
Enroll devices to BMS; verify telemetry tags.
Training
Create QR-linked SOP for custodial/tech teams.
Fault ≤ 0.25% / month Water Savings ≥ 30%

Support

Architect Hub [email protected] Sales: 703-378-2808

Include project name, fixture schedule, finish codes, power/controls notes, and required certifications in your submittal email.

Field Tips

Isolation
Use isolation valves per fixture; label shutoffs clearly.
Power
Label sensor PSUs by zone; log load and circuit IDs.
Closeout
Log firmware/build numbers in closeout documentation.