BathSelect® Heritage Series — Technical Specifications & Advanced FAQ
Heritage Series · Technical Data

BathSelect® Heritage Series — Technical Specifications & Advanced FAQ

Detailed, spec‑grade information for Bauhaus™, Deco™, Modernist™, Renaissance™, Neoclassic™, Brutalist™. Figures below are typical design targets. Always verify the latest cut sheets, BIM families, and wiring diagrams for the exact SKU.

On this page

Bauhaus™ — Technical Specifications

CategorySpecification
Faucet Flow Options0.35 gpm (laminar) · 0.5 gpm (laminar/aerated), pressure‑compensated regulator
Operating Pressure20–80 psi (recommended); below 20 psi reduced flow; add PRV above 80 psi
Inlet Threads3/8" compression (NPSM) braided hoses, 24" typical
Electrical — Battery6 V nominal (4×AA pack); latching solenoid; standby < 100 µA; typical pulse 0.6–0.9 A for 40–80 ms
Electrical — AC/Driver100–240 VAC input → SELV 12 VDC; recommend ≥15 VA per device (≥30 VA per faucet+dispenser set)
Wiring RunsDedicated low‑voltage; 18–22 AWG; max 15 m at 18 AWG (observe voltage drop limits in wiring PDF)
Mounting & TorqueDeck thickness 15–40 mm; faucet shank nut 6–8 N·m; escutcheon/set screws 1.0–1.5 N·m; dispenser collar 2–3 N·m
Sensor WindowIR (850–940 nm) with ToF assist; adjustable range ~80–120 mm; mirror/gloss compensation
Hygiene FlushSelectable after idle 12/24/48/72 h; run 3–8 s; uses tempered water
Thermal PurgeMaintenance function: 60–70 °C (140–158 °F) for 2–5 min; supervised; coordinate with ASSE 1070 mixing
Dispenser TypeLiquid 1–3000 cP; 1000 mL tank; dose 0.8–1.5 mL; anti‑drip; purge/prime routine
Materials/FinishLead‑free brass body; Chrome or PVD (Brushed Nickel, Matte Black, Brushed Gold)
EnvironmentElectronics IP65; ambient 0–50 °C; RH 5–95% non‑condensing
ComplianceDesign intent: ASME A112.18.1/CSA B125.1; NSF/ANSI 61/372; ADA/ICC A117.1 planning

Deco™ — Technical Specifications

CategorySpecification
Faucet Flow Options0.35/0.5 gpm (pressure‑compensated); vandal‑resistant outlet
Operating Pressure20–80 psi; add hammer arrestors on aggressive mains
Inlet Threads1/2" NPSM braided hoses, 24" typical
Electrical — Battery6 V (4×AA); latching solenoid; standby < 120 µA; pulse 0.7–1.0 A / 60 ms
Electrical — AC/DriverSELV 12 VDC; recommend 20 VA per device in high‑traffic venues
Wiring Runs18 AWG up to 20 m; shielded low‑voltage recommended where EMI present
Mounting & TorqueDeck 15–45 mm; shank nut 7–9 N·m; dispenser collar 2.5–3.5 N·m; anti‑rotation gasket included
Hygiene FlushIdle 24/48/72 h; run 4–10 s
Thermal Purge60–70 °C for 3–5 min; supervised; signage/area control required
Dispenser TypeLiquid; 1000 mL; 0.8–1.5 mL dose; anti‑drip; lockout timer 2–4 s
EnvironmentIP65 electronics; cleaning‑chemical tolerant bezels (avoid bleach/abrasives)

Modernist™ — Technical Specifications

CategorySpecification
Faucet Flow Options0.35/0.5 gpm with integrated touchless mixing (ASSE 1070 compatible)
Operating Pressure20–80 psi; maintain balanced hot/cold to mixer
Inlet Threads3/8" compression (hot/cold) + 3/8" outlet to spout/manifold
Electrical — AC/DriverRequired SELV 12–24 VDC; faucet 8 VA typical (peaks 12 VA); dispenser 6 VA typical — size 25–30 VA per set
Electrical — BatteryNot recommended for mixer SKU due to duty cycle
ConnectivityOptional BLE 4.2/5.0 for local commissioning & one‑tap snapshot export (settings, counters); no cloud required
Wiring Runs18 AWG up to 20 m; observe polarity; do not share conduit with mains
Mounting & TorqueDeck 15–40 mm; faucet shank nut 6–8 N·m; mixer manifold screws 2.0 N·m; dispenser collar 2–3 N·m
Hygiene FlushIdle 12/24/48 h; 3–8 s; programmable via service mode/BLE
Thermal Purge60–70 °C for 2–4 min; manual enable only; auto‑revert to tempered
Dispenser TypeLiquid; 1000 mL; 0.8–1.5 mL dose; anti‑drip; purge/prime
EnvironmentIP65; ambient 0–50 °C

Renaissance™ — Technical Specifications

CategorySpecification
Faucet Flow Options0.35/0.5 gpm (laminar outlet recommended for healthcare)
Operating Pressure20–80 psi; maintain clean strainers; flush lines pre‑commissioning
Inlet Threads3/8" compression braided hoses
Electrical — Battery6 V (4×AA); standby < 100 µA; pulse 0.6–0.9 A / 50–70 ms
Electrical — AC/DriverSELV 12 VDC; ≥15 VA per device suggested
Wiring Runs18–22 AWG; max 15 m at 18 AWG; low‑voltage only
Mounting & TorqueDeck 15–40 mm; shank nut 6–8 N·m; dispenser collar 2–3 N·m
Hygiene FlushIdle 12/24/48/72 h; 4–8 s; laminar flow avoids aerosolization
Thermal Purge60–70 °C for 3–5 min; coordinate with infection‑control SOPs
Dispenser TypeFoam; 1000 mL; 0.4–0.6 mL dose; foam pump with purge/prime anti‑clog
EnvironmentIP65 electronics; smooth, easy‑wipe bezels

Neoclassic™ — Technical Specifications

CategorySpecification
Faucet Flow Options0.35/0.5 gpm (laminar/aerated); slim spout geometry for counters
Operating Pressure20–80 psi; pressure regulator integrated
Inlet Threads3/8" compression braided hoses
Electrical — Battery6 V (4×AA); standby < 100 µA; pulse 0.6–0.9 A / 50–70 ms
Electrical — AC/DriverSELV 12 VDC; ≥15 VA per device
Wiring Runs18–22 AWG; up to 15 m; avoid bundling with mains
Mounting & TorqueDeck 12–35 mm; shank nut 6–7 N·m; escutcheon screws 1.0–1.2 N·m; dispenser collar 2–3 N·m
Hygiene FlushIdle 24/48 h; 3–8 s
Thermal Purge60–70 °C for 2–4 min; manual enable
Dispenser TypeLiquid; 1000 mL; 0.8–1.5 mL dose; anti‑drip; purge/prime
EnvironmentIP65; ambient 0–50 °C; RH 5–95% NC

Brutalist™ — Technical Specifications

CategorySpecification
Faucet Flow Options0.35/0.5 gpm; vandal‑resistant outlet; configurable max‑run 15–60 s
Operating Pressure20–80 psi; add arrestors; avoid dead‑end runs
Inlet Threads1/2" NPSM braided hoses, 24" typical
Electrical — Battery6 V (4×AA); standby < 120 µA; pulse 0.7–1.0 A / 60–90 ms
Electrical — AC/DriverSELV 12 VDC; 20 VA per device recommended for high‑abuse sites
Wiring Runs18 AWG up to 20 m; use anti‑tamper conduit where exposed
Mounting & TorqueDeck 15–45 mm; shank nut 8–10 N·m; dispenser collar 3–4 N·m; anti‑rotation gasket & locknut provided
Hygiene FlushIdle 24/48/72 h; 3–8 s; obstruction lockout 30–90 s
Thermal Purge60–70 °C for 3–5 min; supervised; area control
Dispenser TypeLiquid; 1000 mL; 0.8–1.5 mL dose; anti‑drip; vandal shield bezel
EnvironmentIP65 electronics; abrasion‑resistant bezels; cleaning‑chemical tolerant (avoid bleach)

Advanced Technical FAQ

How do I size a shared transformer for a faucet + dispenser set?

Add the worst‑case VA of each device. Example (Modernist set): faucet 12 VA peak + dispenser 10 VA peak → choose ≥25 VA SELV driver. If powering multiple sets, include diversity but keep 20–30% headroom. Keep homeruns short and use 18 AWG to minimize voltage drop.

What’s the expected battery life and how do policy settings affect it?

Battery life depends on cycles/day, water temp, and policies (dwell, lockout, hygiene flush). Latching valves draw only during the open/close pulse. As a rule of thumb: medium traffic (400–600 cycles/day) with hygiene flush off yields 12–18 months; add hygiene flush every 24 h and expect ~10–15% reduction. For 24/7 venues, AC is recommended.

How do I mitigate sensor false triggers near mirrors or glossy stone?

Use models with ToF assist (Bauhaus, Neoclassic) and enable reflective‑surface compensation. Maintain the sensor‑to‑basin offset shown in the cut sheet and keep faucet–dispenser spacing at 150–250 mm (6–10 in) center‑to‑center to avoid cross‑triggering.

What are the recommended hygiene flush and thermal purge practices?

Hygiene flush: 3–8 s after 12–72 h idle to refresh lines. Thermal purge: planned maintenance at 60–70 °C for 2–5 min with area control and signage. Pair with ASSE 1070 mixing valves; auto‑revert to tempered after purge. Log the event in O&M records (BLE snapshot on Modernist).

Which mixing strategy should I use for campuses?

At each lavatory, use ASSE 1070 point‑of‑use mixing to cap outlet temperature. For building‑level control, use ASSE 1017 thermostatic master mixing plus recirculation and commissioning flushes. Keep pressure balance between hot/cold for the Modernist mixer to maintain stable flows.

Any guidance on hydraulic noise and water hammer?

Maintain straight‑run lengths upstream of regulators, keep strainers clean, and use hammer arrestors per code on aggressive mains. Valve timing ramps reduce spikes; if noise persists, add PRVs and verify 20–80 psi operation band.

What soap chemistries are compatible? How do I change products?

Liquid 1–3000 cP across all liquid dispensers; foam models use foam‑specific pumps. Avoid particulates. For alcohol‑based products, verify seal compatibility in the SDS. When switching chemistries, rinse the tank and run the purge/prime routine to clear the lines.

What are the environmental and EMC considerations?

Electronics are IP65 and designed for commercial restroom EM environments. Use dedicated low‑voltage runs, avoid sharing conduits with mains, and keep cable lengths within the wiring diagram limits. In high‑EMI areas (elevators/VFDs), use shielded low‑voltage cable and bond shielding per diagram.

How do I plan for vandal resistance and uptime in public spaces?

Use Brutalist or Deco models with vandal bezels, lockouts, and anti‑rotation gaskets. Specify tamper‑resistant fasteners, add anti‑tamper conduits for exposed low‑voltage runs, and stock spare regulators, seals, and pump modules for rapid swaps.

What finish care is recommended for PVD and Chrome?

Use non‑abrasive cleaners and microfiber. Avoid chlorine bleach and scouring pads. PVD stacks provide high surface hardness and chemical resistance; still, test new housekeeping chemicals on a small area first.

What deck thickness and basin pairing rules should I follow?

Standard deck 12–45 mm depending on model; see spec table above. Pair laminar outlets with shallow basins to reduce splash; align spout projection to fall ~30–50 mm inside the bowl’s deepest zone.

Can I centralize soap with remote tanks?

Yes. Use optional 5 L remote tanks on a per‑bank basis. Follow max lift/line length in the dispenser guide; prime after refill. Label lines for product type to avoid cross‑mixing.

Do these devices store user data?

No personal data is stored. BLE (Modernist) is local‑first and used only for commissioning snapshots (settings and usage counters). No cloud connectivity is required by default.

Note: Values herein are typical targets for the Heritage Series. For stamped submittals, always pull the latest cut sheet, BIM family parameters (.RFA), and wiring diagram PDF for the specific SKU and jurisdiction.